Foxpower’s FBC Series of broadband Cable TV UPS is a cost effective standby power supply designed for powering signal processing equipment in the cable television and broadband LAN distribution systems.It provides a critical load with current-limited, regulated, AC power that is free of spikes, surges, sags and noise. The FBC’s line interactive ferro topology allows it to compensate for input voltage variations of ±30% while providing constant output voltage.
The FBC is an ideal solution for cable operators who need a high quality, very reliable uninterruptible power supply. Features of the FBC include vertical or shelf options, slot for status monitoring card, smart display, terminal block output connections, selectable output taps, external battery temperature probe, built-in chassis handle and replaceable MOV’s.
Product Highlights
FBC Series UPS is developed for global Cable TV and Broadband LAN applications, which is of good performance and high quality thus it contents a lot of strict quality and reliability test standards. Light weight ferro transformer electric design and good impact mechanic design which presents very good convenience to field installment and maintenance. Front panel interface, Smart Menu display together with blue back light LCD module, flexible output selection(48V/63V/87V) will provide customers brand new experience. Modern three-stage battery charging management technology together with battery temperature compensation implementation performs high rate battery charging to expected capacity and also extends battery life a lot
- Line Interactive Ferro transformer Technology (LIFT)
- Wide input voltage range +25%~-30%
- Integrated SCTE HMS/MIB Internet web port with embedded SNMP implemented (Optional)
- Light weight ferro transformer and good impact
- Smart LCD display with blue back light
- Field programmable flash memory and flexible parameters configuration on site
- External battery breaker for fast protection
- IEC standard line cord
Technical Specification
Model | FBC 1336 | FBC 0736E | FBC 0736 | FBC 1148E |
---|---|---|---|---|
Electrical | ||||
Rated input voltage | 115Vrms | 225Vrms | 225Vrms | 225Vrms |
Variation range | +25/-30% (81 to 143Vrms) | +25/-30% (160 to 281Vrms) | +25/-30% (160 to 281Vrms) | +25/-30% (160 to 281Vrms) |
Line return: +20/-25% | Line return: +20/-25% | Line return: +20/-25% | Line return: +20/-25% | |
Nominal input current | 13A | 7A | 7A | 11A |
Input frequency | 60Hz/±3Hz | 60Hz/±3Hz | 50Hz/±3Hz | 50Hz/±3Hz |
Standby mode | ||||
DC voltage | 36Vdc | 36Vdc | 36Vdc | 48Vdc |
Low DC cut-off | 1.75V/cell | 1.75V/cell | 1.75V/cell | 1.75V/cell |
Output | 48/63/87V (Field applicabe) | 48/63/87V (Field applicabe) | 48/63/87V (Field applicabe) | 48/63/87V (Field applicabe) |
Regulation, 87V Tap | ±3% | ±3% | ±3% | ±3% |
Regulation, 63V Tap | ±3% | ±3% | ±3% | ±3% |
Rated output current | 15Arms | 15Arms | 15Arms | 22Arms |
Output configuration | Four promgrammable outputs | |||
Output frequency | 60Hz/±0.1Hz (inverter mode) | 60Hz/±0.1Hz (inverter mode) | 50Hz/±0.1Hz (inverter mode) | 50Hz/±0.1Hz (inverter mode) |
Waveform | Quasi square wave | Quasi square wave | Quasi square wave | Quasi square wave |
Slew rate | <200 V/ms | <200 V/ms | <200 V/ms | <200 V/ms |
<100 V/ms typical | <100 V/ms typical | <100 V/ms typical | <100 V/ms typical | |
Crest Factor (Peak/RMS) | 1:3:1 typical | 1:3:1 typical | 1:3:1 typical | 1:3:1 typical |
Efficiency @87Vrms @100% load | 91% typical | 91% typical | 91% typical | 91% typical |
Efficiency @87Vrms @75% load | 90% typical | 90% typical | 90% typical | 90% typical |
Efficiency @87Vrms @50% load | 88% typical | 88% typical | 88% typical | 88% typical |
Efficiency @87Vrms @25% load | >84% typical | >84% typical | >84% typical | >84% typical |
Inverter operation (40 to 100% load) | 85% typical | 85% typical | 85% typical | 85% typical |
Overload protection | ||||
87V Tap | 24Arms | 24Arms | 24Arms | 24Arms |
63V Tap | 33Arms | 33Arms | 33Arms | 33Arms |
Output short-circuit (@nominal input) | ||||
63V Tap | <150% ratedoutput current | <150% ratedoutput current | <150% ratedoutput current | <150% ratedoutput current |
Overload operation | ||||
0% to 110% Load | Continuous Operation | Continuous Operation | Continuous Operation | Continuous Operation |
115% to 125% load | shutdown output in 30mins | shutdown output in 30mins | shutdown output in 30mins | shutdown output in 30mins |
125% to 150% load | shutdown output in 10mins | shutdown output in 10mins | shutdown output in 10mins | shutdown output in 10mins |
>150% load | shutdown output in 10secs | shutdown output in 10secs | shutdown output in 10secs | shutdown output in 10secs |
Battery charger | ||||
Charge current | 10A | 10A | 10A | 10A |
Temperature compensation | -5mV/Cell/°C (Programmable) | |||
Constant current charge | quick carge to 90% capaity | |||
Constant voltage charge | 2.40V/Cell (Typ. 7hrs) | |||
Ambient Temperature Range | -40°C to 55°C | |||
Humidity | 0 to 95% non-condensing | |||
Elevation | 0 - 3000m | |||
Height (mm) | 198 | 198 | 198 | 198 |
Width (mm) | 465 | 465 | 465 | 465 |
Length (mm) | 290 | 290 | 290 | 290 |
Weight (kg) | 27.5 | 27.5 | 27.5 | 30.5 |
Front panel LCD | 2 x 20 character LCD, blue backlight | |||
LED Indicators | Output status and alarms | |||
Finish | Dark powder coating | |||
Status Monitor | Optional | |||
Abency Compliance | Eletrical safety North America: UL1778, CSA 22.2 No 107.1 Electricl safety International: CE EN62040-1-2 EMI compliance: FCC/IC/CE Class A; CISPR 22/ EN50022; EN 62040-2 |